Electrocardiogram—ST-segment-elevation in lead V4R indicator, yes/no code N
Data Element Attributes
Identifying and definitional attributes | |
Metadata item type: | Data Element |
---|---|
Short name: | Electrocardiogram - ST-segment-elevation in lead V4R |
Synonymous names: | ECG - ST-segment-elevation lead V4R |
METEOR identifier: | 343889 |
Registration status: | Health!, Standard 01/10/2008 |
Definition: | An indicator of whether ST-segment-elevation of greater than or equal to 1mm (0.1mV) in lead V4R of the electrocardiogram (ECG) is present, as represented by a code. |
Data element concept attributes | |
Identifying and definitional attributes | |
Data element concept: | Electrocardiogram—electrocardiogram ST-segment-elevation in lead V4R indicator |
---|---|
METEOR identifier: | 343885 |
Registration status: | Health!, Standard 01/10/2008 |
Definition: | An indicator of whether ST-segment-elevation greater than or equal to 1mm (0.1mV) in lead V4R of the electrocardiogram (ECG) is present. |
Object class: | Electrocardiogram |
Property: | Electrocardiogram ST-segment-elevation in lead V4R indicator |
Value domain attributes | |
Identifying and definitional attributes | |
Value domain: | Yes/no/not stated/inadequately described code N |
---|---|
METEOR identifier: | 301747 |
Registration status: | Health!, Standard 21/09/2005 Housing assistance, Standard 10/02/2006 Community Services (retired), Standard 14/02/2006 Early Childhood, Standard 21/05/2010 Homelessness, Standard 23/08/2010 Independent Hospital Pricing Authority, Standard 01/11/2012 Disability, Standard 07/10/2014 Indigenous, Standard 13/03/2015 Children and Families, Standard 22/11/2016 |
Definition: | A code set representing 'yes', 'no' and 'not stated/inadequately described'. |
Representational attributes | ||
Representation class: | Code | |
---|---|---|
Data type: | Number | |
Format: | N | |
Maximum character length: | 1 | |
Value | Meaning | |
Permissible values: | 1 | Yes |
2 | No | |
Supplementary values: | 9 | Not stated/inadequately described |
Collection and usage attributes | |
Guide for use: | CODE 9 Not stated/inadequately described This code is not for use in primary data collections. |
---|
Data element attributes | |
Collection and usage attributes | |
Guide for use: | CODE 1 Yes ST-segment-elevation >= 1 mm (0.1 mV) in lead V4R CODE 2 No ST-segment-elevation in lead V4R of <= 1 mm (0.1 mV) or no ST-segment-elevation in lead V4R CODE 9 Not stated/inadequately described Includes unknown |
---|---|
Collection methods: | The presence (or absence) of ST-segment elevation in lead V4R should be recorded when right-sided precordial leads are performed in the ECG. |
Comments: | ST-segment elevation in lead V4R represents right ventricular infarction. |
Relational attributes | |
Related metadata references: | See also Electrocardiogram—lead V4R presence indicator, yes/no code N Health!, Standard 01/10/2008 |
Implementation in Data Set Specifications: | Electrocardiogram cluster Health!, Standard 01/10/2008 Conditional obligation: Record when lead V4R was performed on the electrocardiogram. |