Identifying and definitional attributes | |
Metadata item type: | Data Element |
---|---|
Short name: | ECG - Q waves indicator |
METEOR identifier: | 347711 |
Registration status: | Health!, Standard 01/10/2008 |
Definition: | An indicator of whether Q waves are present on a person's follow-up electrocardiogram (ECG), as represented by a code. |
Data Element Concept: | Person— electrocardiogram Q waves indicator |
Value Domain: | Yes/no/not stated/inadequately described code N |
Collection and usage attributes | |
Guide for use: | CODE 9 Not stated/inadequately described This code is not for use in primary data collections. |
---|
Data element attributes | |
Collection and usage attributes | |
Guide for use: | Code 1 Yes Record if Q waves are identified on the follow-up electrocardiogram. Code 2 No Record if no Q waves are identified on the follow-up electrocardiogram. |
---|---|
Collection methods: | Do not record the presence of Q waves for the initial ECG. This data element should only be collected for follow-up ECGs. |
Relational attributes | |
Related metadata references: | See also Electrocardiogram—new Q waves indicator, yes/no code N Health!, Standard 01/10/2008 |
Implementation in Data Set Specifications: | Electrocardiogram cluster Health!, Standard 01/10/2008 Conditional obligation: Record for all follow up electrocardiograms performed after the initial electrocardiogram. |